PRODUCTS
Sciential Solutions' objective is to provide top quality chemicals, along with unmatched customer service and support. Our broad range of polymers include:
Cationic, anionic and non-ionic polyacrylamide flocculants can be supplied in emulsion and dry form. Sciential's broad range of flocculants are manufactured with varied charge levels and molecular weights.
Polyacrylamides
- Anionic powders, beads, emulsions, liquids
- Cationic powders, beads emulsions, liquids, dispersions
- Non-Ionic powders, beads emulsions, liquids
- Linear
- Branched
- Cross-Linked
Polyamines
- Liquid linear
- Liquid branched
PolyDaDMAC
- Low molecular weight liquids
- High molecular weight emulsions, beads
Products are available in totes, drums, pails and 50 lb bags.
|
Product Description
Product Use: Products are used for water and wastewater treatment
Application Use: Flotation, Sedimentation, Dewatering
- Anionic Dry
- Cationic Dry
- Nonionic Dry
Package: Pallet and Break Pallet (50 lb bags)
|
 |
|
|
Product Description
Product Use: Products are used for water and wastewater treatment
Application Use: Flotation, Sedimentation, Dewatering
- Anionic Emulsions
- Anionic Dry
- Cationic Emulsions
- Cationic Dry
- DMDC Coagulant
- Polyamines
Package: Plastic Pail
|
 |
|
|
Product Description
Product Use: Products are used for water and wastewater treatment
Application Use: Flotation, Sedimentation, Dewatering
- Anionic Emulsions
- Anionic Dry
- Cationic Emulsions
- Cationic Dry
- DMDC Coagulant
- Polyamines
Package: Plastic Drum
|
 |
|
|
Product Description
Product Use: Products are used for water and wastewater treatment
Application Use: Flotation, Sedimentation, Dewatering
- Anionic Emulsions
- Anionic Dry
- Cationic Emulsions
- Cationic Dry
- DMDC Coagulant
- Polyamines
Package: Plastic Tote
|
 |
|
CHEMICAL METERING EQUIPMENT
Metering Pumps
Pumps by Sciential Solutions have been manufactured for reliability and precision. The pumps are designed to handle a wide range of chemicals. These pumps feature a full adjustability over the entire operating range. For more information, click meteringpumps@scientialsolutions.com
|
Progressive Cavity Features
- Completely programmable or programmable computer controlled
- LED digital readout display
- Portable/lightweight/durable
- Economical, easy to setup
- Non-pulsating continuous flow
- Quick interchangeable pump units
- Remote control options
- Superior lift capabilities
- Handles light, heavy or viscous fluids
- Available in a wide variety of stators
- Reduces cleanup requirements
Specifications
- Pressure to 350 PSI
- Flows to 200 GPH
- Viscosities to 20,000 CST
- Suction lift up to 28" Hg
- Standard material stainless steel (available in cast iron with tool steel internals)
- Available in Buna N, Hypalon, Viton, plus many other stators
- Standard NEMA 1 enclosures (Optional NEMA 4)
- Repeatable programmable accuracy to 99%
|
 |
| Metering Pump Sizing Performance Chart |
| Volume Per Revolution |
Volume @ 350 RPM Max Speed |
Lbs Per Hour @ 350 RPM |
Unit Weight |
| Series |
Size |
@ 0 PSI in (cm3) |
L/m |
GPM |
GPH |
(Water) S.G. = 1.0 |
lbs. |
| ADBP |
0.4.3 |
1.00 |
0.350 |
0.092 |
5.52 |
45.99 |
32 |
| 0.8.3 |
2.00 |
0.700 |
0.185 |
11.10 |
92.49 |
33 |
| 1.5.3 |
3.75 |
1.313 |
0.347 |
20.82 |
173.5 |
34 |
| ANBP Series also available (larger flows) |
|
|
POLYMER MAKE-DOWN EQUIPMENT |
|
Sciential Solutions provides polymer blending units designed for improved blending and mixing for full activation of liquid polymer in one compact unit. The rugged design provides protection from harsh environments, ease of operation and servicing.
Proper polymer make-down and dosing equipment is vital to achieve optimum efficiency and performance. Sciential Solutions' equipment is engineered to provide proper polymer activation and solution aging and will provide years of trouble-free service.
Our equipment is available for liquid applications with either manual or automatic controls and can be sized to accommodate a wide range of dosage demands.
|
 |
|
TEST KITS
Sciential Solutions' test kits are designed to simulate equipment and process conditions. Our test kits allow the end-user the ability to evaluate and/or optimize new or existing process equipment helping to maintain optimum process separation performance.
Bench scale equipment can produce valuable information about the process performance; such as, effluent quality, chemical type, dosage and equipment sizing criteria.
Bench-scale equipment can be supplied with sample characterization analysis capability or as a component kit, allowing the end-user the flexibility in what is required, thus minimizing cost.
|
Dissolved Air Flotation (DAF) Dissolved air flotation in solids-liquid separation is implemented through the introduction of micron-sized gas (usually air) bubbles into the liquid phase. As the micro bubbles attach to the solids, the resultant buoyant force of the combined solid-gas causes the matrix to rise to the surface where it is collected.
|
 DAF TEST KIT |
|
|
Induced Air Flotation
|
COMING SOON |
|
|
Thickening Sedimentation is the separation or concentration of suspended solids particles from a liquid by settling. Sedimentation can be divided into two operational processes, clarification and thickening. The objective of the thickener is to increase the suspended solids concentration, whereas the objective of the clarifier is to produce a clear effluent.
|
 SEDIMENTATION TEST KIT |
|
|
Clarification Clarification is a method for removing relatively small quantity of suspended solids from a dilute suspension to produce a clarified liquid. The key is balancing the upstream velocity of the liquid and the particle sedimentation velocity.
|
 JAR TEST KIT
|
|
|
Vacuum Filter In a rotary vacuum drum filter, a porous media or filter cloth is supported by the cylindrical drum surface and passes through the sludge vat while the partially submerged drum rotates under applied vacuum (negative pressure). The slurry is sucked from the vat with the liquid passing through the media and the solids retained on the media. The liquid is collected through a series of internal piping and valve arrangement, while the dewatered solids are scraped off the surface of the media.
|
 VACUUM FILTRATION TEST KIT
|
|
|
Pressure Filtration In filter press dewatering, high pressure is directly applied to the sludge against a porous media supported by a plate. Typical pump pressures range from 100 psi to 225 psi. As the pump develops pressure, the sludge is forced onto the media lined plates. The filtrate flows through the media and exit through channels. After a pre-set pressurized time (cycle time), the sludge pump(s) are stopped, the feed line drained, and the press begins to unload. The moving end of the unit retracts and separates the plates, allowing the filter cakes to fall from the plates.
|
 PRESSURE FILTRATION KIT
|
|
|
Belt Press Filter Pretreated (chemically conditioned) feed sludge is introduced to the gravity drain deck where furrowing plows move the sludge to allow free water to drain. As the sludge travels along the belt filter, the sludge is fed into a low pressure wedge zone where the sludge is trapped between the upper and lower belts. As the belts converge on the initial contact point of the first pressure roll, the sludge is dewatered by the increased pressure. Final dewatering occurs in the high pressure zone as the trapped sludge travels through a series of smaller diameter rollers with sharp turns.
|
 BELT PRESS FILTER KIT
|
|
For information on Sciential Solutions' test kits, e-mail your request to testkits@scientialsolutions.com or call (719) 439-8491.
|